92/38, No.12 Street, Quarter 18, Binh Hung Hoa Ward, Binh Tan District, Ho Chi Minh City, Vietnam.
Pressure Reducing Valve
V-COS - Pressure Reducing Valves for Vacuum Steam Processes (with Built-in Separator & Trap)
Price: Contact
Pressure reducing valves for vacuum steam, with built-in separator & trap
V-COS
Benefits and Features
This product is suitable for the vacuum range of steam pressure settings.
Improved Quality of Material Being Heated
- Supplies steam at a stable pressure.
Accuracy of reducing valve's secondary set pressure is within ± 0.01 MPa. Even if the steam flow (load) to the equipment or the primary pressure at the reducing valve changes, the Shock-absorbing Spherical piston (SAS) supplies steam at a constant pressure in order to maintain the temperature of the steam used as the heating source. - Supplies dry steam.
Product features a built-in Cyclone Separator with a 98% condensate separation efficiency. The separator improves the dryness of the steam and removes scale entrained in the steam. The condensate that is separated out is quickly removed through the built-in Free Float® steam trap.
This improvement in the quality of the steam itself also results in an improvement in the heat conductivity of the steam.
Easy to Adjust
- Pressure adjustment is simple, and can be done by using the cover cap as the adjustment spanner.
Long Service Life
- Rust presents a high risk to vital areas of the system. To eliminate this, all major valve components are made of stainless steel to prevent rust and corrosion. Additionally, the inclusion of a strainer in the piping installation prevents the inflow of rust and other debris, protecting the valve components and contributing to a long service life.
Application Areas
Can be used in a variety of steam heating equipment that supplies steam at temperatures of 100 ºC or less.
- Concentration kettles
- Reactor kettles
- Heat exchangers
- Presses
- Dryers, etc.
Product Details
Product Details
Model | Photo | Connection | Body Material | PMO (MPaG) | TMO (°C) | Primary Pressure (MPaG) | Secondary Pressure (MPaG) | Max. Flow Capacity (kg/h) | Specifications | Manual |
---|---|---|---|---|---|---|---|---|---|---|
V-COS | Flanged | Cast Iron (FC250) |
0.2 | 150 | 0.1 - 0.2 | -0.08 - 0.08 | 3000 | Enquire | Enquire |
- PMO = Maximum Operating Pressure
- TMO = Maximum Operating Temperature
Related projects
Category
Online support
Consulting - Quotation
Consulting-Technical
Consulting - Quotation
Consulting - Technical
Consulting - Quotation
Featured products