Thermal Mass Flow Meter
Price: Contact
TGF600 Series thermal mass flow meter measures the gas mass flow base on thermal diffusion theory. It has two filmed RTD’s as its sensors, one of which sense the velocity of the gas flow (RH) and the other one will detect the temperature shift of the gas flow (RMG). When the two RTD are in the gas flow ,the RH will be heated while the RMG will sense the temperature changing of the gas flow. More heat will be taken away as the velocity of the gas flow increasing, so the temperature on RH will decline.
TGF600 Thermal mass flow meter for industrial gases
TGF600 Series thermal mass flow meter measures the gas mass flow base on thermal diffusion theory. It has two filmed RTD’s as its sensors, one of which sense the velocity of the gas flow (RH) and the other one will detect the temperature shift of the gas flow (RMG). When the two RTD are in the gas flow ,the RH will be heated while the RMG will sense the temperature changing of the gas flow. More heat will be taken away as the velocity of the gas flow increasing, so the temperature on RH will decline.
Features of TGF600 thermal mass flow meter
- Direct mass flow or normal flow measurement
- 100:1 turn down ratio in 5 ranges: 0.3~30Nm/s, 0.6Nm/s~60 Nm/s, 0.9~90Nm/s, 1.2~120Nm/s, or 1.5~~150Nm/s
- No pressure loss, suitable for pipe in any shape with known sectional area
- For the insertion type, installation and maintenance can be finished on line
- High accuracy data acquisition circuit to ensure outstanding repeatability and accuracy
- High efficiency design of power supply, the total power consumption is only 60mA@24VDC
- Self-diagnose function plus remote diagnose function, ensure easier trouble-shooting
- Bluetooth communication for reading, setting and diagnosis and COMMATE APP
- Ex-proof version optional
Specification of TGF600 thermal mass flow meter
| Media Compatibility | Air, Nitrogen, O2, CO2, Argon, CH4, Natural gas, biogas, and almost all dry and clean air |
| Pipe diameter | Insertion:DN25~900mm |
| Inline: DN25~300mm | |
| Flow velocity range | 0.3~30Nm/s |
| 0.6~60Nm/s | |
| 0.9~90Nm/s | |
| 1.2~120Nm/s | |
| 1.5~150Nm/s | |
| 1.8~180Nm/s | |
| Accuracy | 1.5% RD ±0.5% FS |
| Temperature of medium | Standard: -40 ~ +150°C |
| Middle: -40 ~ +250°C | |
| High: -40 ~ +450°C | |
| Pressure of medium | Insertion: 1.6 MPa |
| Flanged insertion: 6.3 Mpa | |
| Flanged in-line: 6.3 Mpa | |
| Power supply | AC85~264V or DC16~32V |
| Response time | 1 second |
| Output | Frequency and 4~20mA as standard |
| RS~485+Bluetooth as standard | |
| Communication | 4~20mA@HART as optional |
| Date displayed | Mass flow, Total flow |
| Volume flow in normal condition | |
| Ingress protection grade | IP65 (GB China) |
| Ex-proof | NEPSI EX d II c T3 Gb |
Max pipe size that each probe can adapt to
| Probe length | 290mm | 440mm | 690mm | 1000mm | 1500mm |
| T<50 dgr C | DN150 | DN450 | DN900 | DN1500 | DN2500 |
| 50 dgrC |
/ | DN100 | DN600 | DN1200 | DN2200 |
| 150 dgrC |
/ | / | DN400 | DN1000 | DN2000 |
| 250 dgrC |
/ | / | DN300 | DN600 | DN1000 |
| T<122 dgr F | 6″ | 18″ | 36″ | 60″ | 100″ |
| 122 dgr F |
/ | 4″ | 24″ | 48″ | 88″ |
| 302 dgr F |
/ | / | 16″ | 40″ | 80″ |
| 482 dgr F |
/ | / | 12” | 24” | 40” |
| 1 | General model | TGF600 | Standard | |
| 2 | Fluid type | 1 | Air/nitrogen | Standard |
| 2 | Oxygen (sensor will be degreased) | Option | ||
| 3 | Other (Please advsise gas composition) | Option | ||
| 3 | Measurement velocity | 1 | 0.3 ~ 30Nm/s | Option |
| 2 | 0.6 ~ 60Nm/s | Standard | ||
| 3 | 0.9 ~ 90Nm/s | Option | ||
| 4 | 1.2 ~ 120Nm/s | Option | ||
| 5 | 1.5 ~ 150Nm/s | Option | ||
| 6 | 1.8 ~ 180Nm/s | Option | ||
| 4 | Process connection | I1 | Insertion type with 290mm probe | Option |
| I2 | Insertion type with 440mm probe | Standard | ||
| I3 | Insertion type with 690mm probe | Option | ||
| I4 | Insertion type with 1000mm probe | Option | ||
| I5 | Insertion type with 1500mm probe | Option | ||
| F1 | Flanged insertion type up to 25 barG (362 psiG) | Option | ||
| F2 | Flanged insertion type up to 40 barG (580 psiG) | Option | ||
| F2 | Flanged insertion type up to 63 barG (913 psiG) | Option | ||
| D1 | Flanged DIN PN16 up to 16 barG (232 psiG) (DN15~DN300) | Option | ||
| D2 | Flanged DIN PN25 up to 25 barG (362 psiG) (DN15~DN300) | Option | ||
| D3 | Flanged DIN PN40 up to 40 barG (580 psiG) (DN15~DN300) | Option | ||
| D4 | Flanged DIN PN63 up to 63 barG (913 psiG) (DN15~DN300) | Option | ||
| C1 | Flanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch~12 inch) | Option | ||
| C2 | Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch~12 inch) | Option | ||
| C3 | Flanged ANSI CL400 up to 63 barG (913 psiG) (0.5 inch~12 inch) | Option | ||
| J1 | JIS 10K up to 16 barG (232 psiG) (DN15~DN300) | Option | ||
| J2 | JIS 20K up to 40 barG (580 psiG) (DN15~DN300) | Option | ||
| J3 | JIS 30K up to 63 barG (913 psiG) (DN15~DN300) | Option | ||
| 5 | Wet part material | 1 | 316ss sensor with 304ss wet parts | Standard |
| 2 | 316ss sensor with 316ss wet parts | Option | ||
| 6 | Medium temp range | N | <150°C | Standard |
| Q | <250°C | Option | ||
| H | <450°C (please select remote display also) | Option | ||
| 7 | Transmitter | T | Integral | Standard |
| R | Remote | Option | ||
| 8 | Cable grinder | M | M20x1.5 | Standard |
| N | NPT 1/2 | Option | ||
| 9 | Ex-proof | N | No Ex-proof | Standard |
| 1 | NEPSI Ex d IIC T3 Gb | Option | ||
| 10 | Transmitte | 1 | pulse/frequency + 4~20mA + RS485 + Bluetooth | Option |
| 2 | pulse/frequency + 4~20mA@HART + Bluetooth | Standard | ||
| 11 | Power supply | 1 | 13.5~42VDC | Standard |
| 2 | 13.5~42VDC with 85~265VAC 50/60Hz power converter | Option | ||
| 12 | Pipe size | xxxx | please use 4 digit pipe size, such as DN50=0050, DN300=0300 | xxxx |
Document