92/38, No.12 Street, Quarter 18, Binh Hung Hoa Ward, Binh Tan District, Ho Chi Minh City, Vietnam.

Thermal Mass Flow Meter

TGF600 Thermal mass flow meter for industrial gases

Price: Contact

  • Model: TGF600
  • TGF600 Series thermal mass flow meter measures the gas mass flow base on thermal diffusion theory. It has two filmed RTD’s as its sensors, one of which sense the velocity of the gas flow (RH) and the other one will detect the temperature shift of the gas flow (RMG). When the two RTD are in the gas flow ,the RH will be heated while the RMG will sense the temperature changing of the gas flow. More heat will be taken away as the velocity of the gas flow increasing, so the temperature on RH will decline.

  • Origin: China
  • TGF600 Thermal mass flow meter for industrial gases

    TGF600 Series thermal mass flow meter measures the gas mass flow base on thermal diffusion theory. It has two filmed RTD’s as its sensors, one of which sense the velocity of the gas flow (RH) and the other one will detect the temperature shift of the gas flow (RMG). When the two RTD are in the gas flow ,the RH will be heated while the RMG will sense the temperature changing of the gas flow. More heat will be taken away as the velocity of the gas flow increasing, so the temperature on RH will decline.

     

    Features of TGF600 thermal mass flow meter

    • Direct mass flow or normal flow measurement
    • 100:1 turn down ratio in 5 ranges: 0.3~30Nm/s, 0.6Nm/s~60 Nm/s, 0.9~90Nm/s, 1.2~120Nm/s, or 1.5~~150Nm/s
    • No pressure loss, suitable for pipe in any shape with known sectional area
    • For the insertion type, installation and maintenance can be finished on line
    • High accuracy data acquisition circuit to ensure outstanding repeatability and accuracy
    • High efficiency design of power supply, the total power consumption is only 60mA@24VDC
    • Self-diagnose function plus remote diagnose function, ensure easier trouble-shooting
    • Bluetooth communication for reading, setting and diagnosis and COMMATE APP
    • Ex-proof version optional

     

    Specification of TGF600 thermal mass flow meter

    Media Compatibility Air, Nitrogen, O2, CO2, Argon, CH4, Natural gas, biogas, and almost all dry and clean air
    Pipe diameter Insertion:DN25~900mm
    Inline: DN25~300mm
    Flow velocity range 0.3~30Nm/s
    0.6~60Nm/s
    0.9~90Nm/s
    1.2~120Nm/s
    1.5~150Nm/s
    1.8~180Nm/s
    Accuracy 1.5% RD ±0.5% FS
    Temperature of medium Standard: -40 ~ +150°C
    Middle: -40 ~ +250°C
    High: -40 ~ +450°C
    Pressure of medium Insertion: 1.6 MPa
    Flanged insertion: 6.3 Mpa
    Flanged in-line: 6.3 Mpa
    Power supply AC85~264V or DC16~32V
    Response time 1 second
    Output Frequency and 4~20mA as standard
    RS~485+Bluetooth as standard
    Communication 4~20mA@HART as optional
    Date displayed Mass flow, Total flow
    Volume flow in normal condition
    Ingress protection grade IP65 (GB China)
    Ex-proof NEPSI EX d II c T3 Gb

     

    Max pipe size that each probe can adapt to

    Probe length 290mm 440mm 690mm 1000mm 1500mm
    T<50 dgr C  DN150 DN450 DN900 DN1500 DN2500
    50 dgrC / DN100 DN600 DN1200 DN2200
    150 dgrC / / DN400 DN1000 DN2000
    250 dgrC / / DN300 DN600 DN1000
    T<122 dgr F 6″ 18″ 36″ 60″ 100″
    122 dgr F / 4″ 24″ 48″ 88″
    302 dgr F / / 16″ 40″ 80″
    482 dgr F / / 12” 24” 40”

     

    1 General model TGF600   Standard
    2 Fluid type 1 Air/nitrogen Standard
    2 Oxygen (sensor will be degreased) Option
    3 Other (Please advsise gas composition) Option
    3 Measurement velocity 1 0.3 ~ 30Nm/s Option
    2 0.6 ~ 60Nm/s Standard
    3 0.9 ~ 90Nm/s Option
    4 1.2 ~ 120Nm/s Option
    5 1.5 ~ 150Nm/s Option
    6 1.8 ~ 180Nm/s Option
    4 Process connection I1 Insertion type with 290mm probe Option
    I2 Insertion type with 440mm probe Standard
    I3 Insertion type with 690mm probe Option
    I4 Insertion type with 1000mm probe Option
    I5 Insertion type with 1500mm probe Option
    F1 Flanged insertion type up to 25 barG (362 psiG) Option
    F2 Flanged insertion type up to 40 barG (580 psiG) Option
    F2 Flanged insertion type up to  63 barG (913 psiG) Option
    D1 Flanged DIN PN16 up to 16 barG (232 psiG) (DN15~DN300) Option
    D2 Flanged DIN PN25 up to 25 barG (362 psiG) (DN15~DN300) Option
    D3 Flanged DIN PN40 up to 40 barG (580 psiG) (DN15~DN300) Option
    D4 Flanged DIN PN63 up to 63 barG (913 psiG) (DN15~DN300) Option
    C1 Flanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch~12 inch) Option
    C2 Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch~12 inch) Option
    C3 Flanged ANSI CL400 up to 63 barG (913 psiG) (0.5 inch~12 inch) Option
    J1 JIS 10K up to 16 barG (232 psiG) (DN15~DN300) Option
    J2 JIS 20K up to 40 barG (580 psiG) (DN15~DN300) Option
    J3 JIS 30K up to 63 barG (913 psiG) (DN15~DN300) Option
    5 Wet part material 1 316ss sensor with 304ss wet parts Standard
    2 316ss sensor with 316ss wet parts Option
    6 Medium temp range N <150°C Standard
    Q <250°C Option
    H <450°C (please select remote display also) Option
    7 Transmitter T Integral Standard
    R Remote Option
    8 Cable grinder M M20x1.5 Standard
    N NPT 1/2 Option
    9 Ex-proof N No Ex-proof Standard
    1 NEPSI Ex d IIC T3 Gb Option
    10 Transmitte 1 pulse/frequency + 4~20mA + RS485 + Bluetooth Option
    2 pulse/frequency + 4~20mA@HART + Bluetooth Standard
    11 Power supply 1 13.5~42VDC Standard
    2 13.5~42VDC with 85~265VAC 50/60Hz power converter Option
    12 Pipe size xxxx please use 4 digit pipe size, such as DN50=0050, DN300=0300 xxxx

     

     

    Document

    TGF600 datasheet

     

     

     

    Related projects

    Category
    Online support
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting-Technical
    Consulting-Technical
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting - Technical
    Consulting - Technical
  • Consulting - Quotation
    Consulting - Quotation