92/38, No.12 Street, Quarter 18, Binh Hung Hoa Ward, Binh Tan District, Ho Chi Minh City, Vietnam.

Differential Pressure Flow Meter

PTF600 differential pressure type flow meter

Price: Contact

  • Model: PTF600
  • PTF600 Pitot tube flow meter is COMATE’s heavy duty designed flow meter for wet and dry air. It has an wide turn down DP transmitter which ensures it a 33:1 wide measurement range and better stability. It has an unique water-proof design which can solve the problem that caused by condensing water in capillary.

  • Origin: China
  • PTF600 differential pressure type flow meter

    PTF600 Pitot tube flow meter is COMATE’s heavy duty designed flow meter for wet and dry air. It has an wide turn down DP transmitter which ensures it a 33:1 wide measurement range and better stability. It has an unique water-proof design which can solve the problem that caused by condensing water in capillary.

    PTF600 Pitot tube flow meter also has integral temperature and pressure compensation, so it can measure standard flow, temperature and pressure also.

    Features of PTF600 differential pressure type flow meter

    • Measures flow rate, temperature, pressure, FAD measurement available
    • Heavy duty design, more durable in tough measurement environment
    • Super wide turn down of 33:1, best in market
    • Wide measurement range & Fast response time
    • Insertion mounting, available for hot tapping
    • Cellphone APP for reading and setting
    • Self-diagnose and remote diagnose function to provide with best support
    • For both dry and wet air measurement, possible for measuring compressed air at output of compressor

     

    Specification of pTF600

    Fluid compatibility Dry and wet air
    Pipe size range Insertion type: DN25~400mm
    Inline type: DN15~300mm
    Different pressure range 6~6220 Pa, please reference to next
    subject on how to calculate flow rate
    range
    Flow Accuracy 1.0%RD±0.5%FS
    Ambient temperature -20~60℃
    Ambient humidity 5~100%
    Process connection 1/2 G insertion with ball valve
    Pressure rating Insertion type :16 barG
    Inline type : 4 Mpa
    Fluid temperature -40~ 120℃
    Wet part material 304ss
    Parameter measured Mass flow, Volume flow in normal condition,
    Total flow, Temperature of medium. Velocity
    Power 13.5~32V DC,150mA max
    Communication RS485@Modbus-RTU, blue tooth
    Response time 1 second

     

    Read & Set on in COMATE APP

    Instead of traditional keyboard, PTF600 implement a cellphone setting system. All PTF520 have Bluetooth communi-cation.
    Users can install COMATE APP on their cellphone or tablet and use the APP to connect with a PTF600 flow meter to read or set the flow meter.
    This APP also support a remote diagnose function. Whenever there is anything wrong with the flow meter, customer can ask for a remote diagnose support. When this function is working, COMATE engineer back in office can remotely check the setting of the meter, and the signal of sensor, to provide users with most accurate trouble shooting advise.

    COMATE APP has made the using of the product simple and efficient.

     

    Model Selection

    1 General model PTF600
    I1 Insertion type with 255mm probe Standard
    2 Process connection I2 Insertion type with 320mm probe Option
    I3 Insertion type with 395mm probe Option
    F1 Flanged insertion type up to 25 barG (362 psiG) Option
    F2 Flanged insertion type up to 40 barG (580 psiG) Option
    D1 Flanged DIN PN16 up to 16 barG (232 psiG) (DN15~DN300) Option
    D2 Flanged DIN PN25 up to 25 barG (362 psiG) (DN15~DN300) Option
    D3 Flanged DIN PN40 up to 40 barG (580 psiG) (DN15~DN300) Option
    C1 Flanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch~12 inch) Option
    C2 Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch~12 inch) Option
    J1 JIS 10K up to 16 barG (232 psiG) (DN15~DN300) Option
    J2 JIS 20K up to 40 barG (580 psiG) (DN15~DN300) Option
    3 Transmitter T Integral Standard
    R Remote Option
    4 Transmitte 1 pulse/frequency +  RS485 + Bluetooth Standard
    2 pulse/frequency + 4~20mA + RS485 + Bluetooth Option
    5 Power supply 1 13.5~42VDC Standard
    2 13.5~42VDC with 85~265VAC 50/60Hz power converter Option
    6 Pipe size xxxx please use 4 digit pipe size, such as DN50=0050, DN300=0300 xxxx

     

    Document:

    PTF600 datasheet

     

    Related projects

    Category
    Online support
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting-Technical
    Consulting-Technical
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting - Technical
    Consulting - Technical
  • Consulting - Quotation
    Consulting - Quotation