Ammete China Water Meter
Price: Contact
A high-precision smart meter that uses photoelectric sensors to read wheel digits directly, ensuring zero-error data transmission for remote management.
Product Description
Application:
A high-precision smart meter that uses photoelectric sensors to read wheel digits directly, ensuring zero-error data transmission for remote management.
Key Features:
• Direct Reading: Reads the wheel digits directly with zero cumulative error.
• No Power Needed: Only consumes energy during the instant of remote reading.
• Precision Sensing: Advanced photoelectric technology ensures high data reliability.
• Anti-Interference: Immune to external magnetic fields and mechanical vibrations.
• Long Lifespan: Non-contact measurement reduces wear on internal components.
• Smart Integration: Seamlessly connects to M-Bus or RS-485 systems.
• IP68 Protection: Fully sealed design for stable operation in damp environments.
• Instant Billing: Provides real-time data for accurate and efficient water management.
Specifications:
• Body material: Cast iron
• Accuracy: R80/ R100
• Size: DN15-20-25
• Cold water: 0 ℃ - 50℃ / Hot water 0 ℃ - 90℃
• Water pressure: 1.0MPa / 1.6MPa
• △P≤63
• Connecting threaded option: G/ BSP/ NPT
• Transmission: M-Bus/ RS485
Installation:
• Install horizontally with the register facing up for accurate sensing and reading.
• Keep the communication cable away from high-voltage power lines to avoid interference.
• Ensure all wire connections are properly sealed with waterproof heat-shrink tubing.
Wiring Table:
|
Wire Table |
|
|
Red Wire |
+12V (Power Supply) |
|
Black Wire |
GND (Ground) |
|
Yellow Wire |
RS485 A |
|
Blue Wire |
RS485 B |
Communication:
|
Communication Settings |
|
|
Protocol |
Modbus-RTU |
|
Baud Rate |
9600 bps (Default) |
|
Date Format |
8 Data Bits No Parity 1 Stop Bit |
|
Slave ID |
The last two digits of the 8-digit serial number on the meter |
Address Table:
|
Register Address (Hex) |
Description |
Length |
Data Format |
|
0000H - 0001H |
Total Water Consumption |
4 Bytes |
32-bit Integer |
|
0015H (High Byte) |
Device Address (Slave ID) |
1 Byte |
1 - 247 |
|
0015H (Low Byte) |
Baud Rate Setting |
1 Byte |
01=9600 (Default) |
Accuracy:
• From minimum flow rate (Q1) inclusive, to transitional flow rate (Q2) exclusive: ±5%
• From transitional flow rate (Q2) inclusive, to overload flow rate (Q4) exclusive: ±2%
• Hot water meter ±3%
Technical Data:
|
Model |
Unit |
AMT PEC-A |
AMT PEC-B |
AMT PEC-C |
|
|
Nominal Size |
mm(inch) |
15(1/2'') |
20(3/4'') |
25(1'') |
|
|
Overload Flow Rate (Q4) |
m3h |
3.125 |
5 |
7.875 |
|
|
Permanent Flow Rate (Q3) |
m3h |
2.5 |
4 |
6.3 |
|
|
R=80 |
Transitional Flow Rate (Q2) |
m3/h |
0.05 |
0.08 |
0.126 |
|
Minimum Flow Rate (Q1) |
m3/h |
0.0312 |
0.05 |
0.0787 |
|
|
R=100 |
Transitional Flow Rate (Q2) |
m3/h |
0.04 |
0.064 |
0.1 |
|
Minimum Flow Rate (Q1) |
m3/h |
0.025 |
0.04 |
0.063 |
|
|
Min. Reading |
m3 |
0.0001 |
0.0001 |
0.0001 |
|
|
Max. Reading |
m3 |
9999 |
9999 |
9999 |
|
|
Temperature class |
T °C |
T50/T90 |
|||
|
Water pressure classes |
MPa |
1.0/1.6 |
|||
|
Pressure-loss classes |
|
△P63 |
|||
|
Installation Positions |
|
HORIZONTAL |
|||
Dimension:
|
Model |
Nominal Size (mm) |
Size (inch) |
Length (mm) |
Width (mm) |
Height (mm) |
Connecting Thread D |
|
AMT PEC-A |
15 |
1/2″ |
165 |
85 |
120 |
G¾B |
|
AMT PEC-B |
20 |
3/4″ |
195 |
90 |
120 |
G1 B |
|
AMT PEC-C |
25 |
1″ |
225 |
90 |
120 |
G1¼B |